> Verify the whiter igniter is firmly inserted into the white or orange connector. Basically,thermopile in an open circuit test reads 650 to 850 millivolts. Verify the water pipes are properly insulated and ventilated. You may have to dim the room lights in order to see . There is no particular reset button on your Honeywell water heater digital thermostat. If you cant find the problem, or the problem is too advanced, dont hesitate to call a licensed service professional. Just drain the water and do a flush in the tank. We will tell you all the reasons behind each issue with their simple solutions. link to What Kind Of Paint For Garage Walls? Look though the sight glass for a small, blue spark while pressing the igniter button repeatedly. One possibility is that the power to control may have been lost. Make sure the white igniter is snugly inserted into the white or orange connector. To determine if the igniter is defective, first make sure the igniter is getting voltage. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. You will need to wait a few minutes, in between lighting it. Then, ensure that the reset button of the thermostat is working correctly. Another serious problem you can often experience is yourHoneywell water heater wont ignite. Replace the bad thermopile with the help of the technician. COPYRIGHT 2023. Finally, inspect and replace the broken anode rod. Sometimes, electronic ignition water heaters wont light due to improper voltage or loose wires. Water heaters are not appliances that are relatively safe to work with. Inspect the flex tube to test whether it is kinked from any portion. Make a proper adjustment to the thermostat. Faulty Gas Control Valve's Electrical Connections 5. Continue with Recommended Cookies. If you are unsure about what you are doing, do not hesitate to call a service professional. If the pilot flame lights and then goes out after youve released the gas control knob, provided you have held it in for the recommended 20 to 30 seconds, this is a strong indication of a thermocouple malfunction. Clean the thermocouple and replace it if needed. If your electronic ignition water heater, will not light, then it could be a loose wire, the ignition may not be getting the correct voltage, or you may just need to try lighting it more than once. At the same time as youre holding down the pilot switch, press on the piezo igniter. A brief visual inspection will generally help you discover possible issues with your pilot flame. If the pilot light wont light and there is no spark, the problem usually lies with the spark electrode. This issue is most likely caused by one of the following: If your gas water heater has an electronic ignition system, you should never attempt to light it by hand. Continuously thermopile generates electric power while the gas valve/temperature knob is turned off. The blinking light on a different number of times indicates that theres something up with your water heater and needs to be fixed as soon as possible. In some instances, you may need to push the knob down in order to turn it from Pilot to OFF. Check all wiring connections. Other reasons for this problem are: There are a few possible causes for a malfunctioning Honeywell water heater igniter. Whatever the problem, first reset your heater and find if resetting could fix your heater issues or not. We will get back to you ASAP. That's why you should inspect these two elements first and repair or replace them to let the status light blink again. Weve also outlined some other common water heater pilot light problems and how to fix them. The thermocouple detects the pilot flame. It may also be caused due to a failing pressure switch. Consequently, the pilot wont light and the status light will not blink. Now you know why the status light of your Honeywell water heater doesnt work. 2 - Replace Pilot Assembly Insufficient power to the gas control valve/thermostat. If it doesnt work, you need to replace the corresponding defective part. Wait for a while and look for any corrosion on the electrical connection. Disconnect and rejoin the wires. If no spark is coming, check the igniter connection for any corrosion. By using this troubleshooting method, you can avoid replacing expensive parts, that may not have been broken. Check for gas leaks. The first option is to clear out and remove any deposits from the pilot, ensuring that it can ignite easily and early enough to light your boilers gas before it runs out of air. Manage Settings Also, connect the black lead to the white wire. The main reason for the Honeywell water heater not becoming hot enough is the malfunctioning of the thermostat. In some cases, the electronic control board is the culprit. Now check for sediment build-up at the bottom of the tank as it may be the culprit for reducing the amount of heat. Whatever type of sound the Honeywell water heater makes, you should fix this sound in the following ways: YourHoneywell water heater not heatingmeans the heaters ignition system is not working correctly. Sometimes, faulty electrical wiring connectors to the thermocouple, igniter, and thermal switch create a problem. Do not try to light it manually, to avoid safety issues. Save my name, email, and website in this browser for the next time I comment. Try lighting the pilot following the lighting instructions on the water heater and visually confirm the pilot can be lit. Another solution is resetting the unit by pressing and holding down both buttons for three seconds. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. So, as for the first step, you have to check whether there is light on the pilot. Get free, zero-commitment quotes from pro contractors near you. 7 Flashes = Gas Control Valve Failure. Your Do You Need Water Heater Repair Services? Repair the damaged part as soon as possible. (Seconds! When you click on the igniter, there should be a tiny spark happening inside of the pilot. Throughout this article, we have assembled all the aspects behind the Honeywell water heater status light not blinking issue. Over time, carbon and fuel residue form a layer on the thermopile. Also, check the wiring connection. Therefore, you should always consult the instructions from your manufacturer. Chances are there may be an easy fix or a fix that you can do yourself, without calling in a plumber. ), blinking light on a different number of times, How to fix Honeywell water heater status light blinking 7 times, How to fix Honeywell water heater status light blinking 3 times, water heater shuts down due to a high temperature, Honeywell water heater light is not blinking, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Or, the defective spark electrode itself. Reset the tripped thermal switch. Then, check to see if the water line is correctly connected to the heater. Comment and tell us whether you successfully solved your Honeywell heaters issues or not. So, lets start. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. The error codes flashes 0, 1, 2, 4, 5, 7, & 8 times. When you cant get your water heater to light, you may get a little bit irritated. It must measure at least 19.5VAC with the igniter powered. Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. Step #4: Take a look at the viewport to see if the pilot light comes on. Here are some instructions on how to do so. Then, proceed with relighting the pilot per the steps outlined above. If the water heater is leaking, you may also see water on the floor or in the sink. Heater Flammable Vapor Sensor Lockout 7. If you suspect that your water tank is leaking, call a professional to repair the damage. It ensures a constant flame to light the burner. And you will surely learn to fix your Honeywell heater issues by yourself. As a result, it will not work the way it should. Take the help of an electrician to repair the damaged wiring issue. Turn the control knob to the OFF position. Your heaters burner fails to ignite mainly for the following factors: For fixing the above difficulties, the easy resolving ways are: Honeywell water heater overheatingis one of the potentially dangerous issues with your gas water heater. Kit includes: piezo igniter and instructions; For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater The last issue, after you have determined that there is no easy fix, is that the main control valve could be bad. Finally, verify the igniter is working properly by relighting the pilot following the lighting instructions on the manual. Then try again to relight the pilot. Manage Settings The most common cause for a pilot light that repeatedly goes out on a gas water heater is a damaged, dirty, bent, or faulty thermocouple. Its essential to regularly clean your water filter to avoid this issue, and if you find that its already clogged, youll need to replace it. If your hot water heater suddenly stops working, chances are a bad thermocouple has shut off the gas to the pilot light. Your IP: All Right Reserved by HeaterFixLab. 8 Flashes = Power off Failure. Due to inadequate gas, your heater fails to ignite and heat the water. If you have been having trouble with your hot water heater not igniting, then there could be several issues. But before moving to the detailing part, let us walk you through a quick table highlighting all the possible reasons with quick solutions:Probable ReasonsPossible SolutionsThe pilot is not lighting> Clean out the pilot tube.> Relight the pilot following proper instructions.No spark at the igniter> Verify the whiter igniter is firmly inserted into the white or orange connector.> Clean the corroded igniter connection with sandpaper. Check and clean out the debris from the tube using a needle or this type of object. If your water heater has a digital readout or an automatic reset thermostat, its likely working. FV sensors also go into lockout mode when the sensor becomes damaged or defective. Most newer hot water heaters use an electronic igniter, this means that you will not be able to manually light it, the way you could with an older one. It may need to be replaced or re-tipped. Anyway,the process to test your own thermopile is relatively simple. Heater Overheating 9. The action you just performed triggered the security solution. Attach the red positive lead to the red thermopile wire. It may be rust, oil, grime, dirt, or excess air in the system. For instance: Follow the below instruction to resolve the above igniter issues: First up, you have to check the wiring connection of the igniter. Locate the thermopile on the burner assembly. Most modern water heaters no longer have standing pilots. The water heaters safety devices are FV (Flammable Vapor) sensors. However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot. You need to replace the damaged or faulty FV sensor when it doesnt get out of the lockout mode even after resetting it. If needed, rub the connection with sandpaper. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. 2. Note: You can also read how to fix Honeywell hot water heater status light blinking 7 times. Also, make sure there are no flammable vapor-creating objects like paint, or gasoline nearby the heater. Using your manual, enter the thermostat configuration and change the system type setting and re-attempt to call for heat/ return to step 1. > Bad outer poor thermostat knob/gas control valve set to on position. If its a Honeywell water heater, follow the steps I mentioned to make the replacement with ease. Your Honeywell water heater can leak from the bottom due to the improperly maintained drain valve. > Replace the bad outer door, & defective gas control valve/ thermostat. The control board will throw a code if there is a problem with the voltage. Clean the pilot tube using a sharp object to remove the blockages. If the electrode is faulty or broken, replace the electrode entirely. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. If you find any wire or plug broken you can call the electrician to fix it. And thus your water heater can leak. Better safe than sorry. Honeywell Ignitor - How to Replace a Water Heater Ignitor FIX IT Home Improvement Channel 98.1K subscribers Subscribe 213 65K views 8 years ago Subscribe and visit our weekly FIX IT Home. The thermocouple could be damaged and will need to be replaced, or it may just be loose. When done, connect the outer door and check the status light. Pilot lights can take a few tries to get lit. Yes, you can replace an igniter on a gas water heater. What are the symptoms of a broken water heater? Ensure your heater is getting adequate gas pressure, Correctly set the thermostat setting (Not too high or too low), Clean your heater pilots carbon deposit to remove its restriction, Lint/dust blocked the FVIR flame arrestor, Turn on your heaters temperature dial to set the desired temperature, Replace the not-functioning or damaged thermostat, Properly clean the main burner lines blockage, blocked FVIR flame arrestor, and filthy filter, Gas valve and thermostat assembly malfunction, Shorted out or malfunctioning heating element, Replace the malfunctioning thermostat, defective gas valve and thermostat assembly, and faulty heating element, Set your heaters temperature at the perfect level, Spiders in the pilot line or clogged line, Following the manufacturers instructions, turn your heaters knob clockwise or counterclockwise, Unscrew the pilot line, properly clean it or replace it, Ensure your heaters safety mechanism is working properly, Lose drain valve, or the valve is not closed completely, Faulty or leak temperature and pressure relief valve. When you have a problem with your water heater, you will need to do some troubleshooting and some testing. If your pilot flame lights but keeps going out, its vent is most likely dirty and/or clogged. Required Part Water Heater Igniter If you move through this list, and still cannot find the problem, then you know it is time to call in a professional. Set the thermostat or the device's controller slightly above the current room temperature. The root reasons behind Honeywell hot water heater no status light includes: Furthermore, due to tripped thermal switch, lack of combustion air, and defective heater thermopile, owners will face no status light blinking issue on their water heaters. The igniter on Honeywell water heater won't work because of these three reasons: Igniter wires come loose from the white connector The thermopile gets covered with carbon deposits The igniter itself is bad If you want to ignite the unit again to comfort the ice-cold conditions, you must address those issues and solve them. If the light switch is not the issue, then the water heater may need to be serviced. If your heaters status light wont blink, turn off the gas valve and release the gas control knob. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. After resolving the pilot issue and there is still no blinking on the status light, a bad igniter or malfunctions from the igniter is the second suspect. Get free, zero-commitment quotes from pro contractors near you. The igniter will have multiple wires that go to it. Ensure the valve is properly tightened to the connection. Typically, an igniter on a water heater lasts around 7 to 15 years. I'm a writer that is passionate about home improvements, remodeling, and renovating. Also, periodically clean your water heater and its internal components. In this stage, what you need to do is to take everything out that leads into the gas control valve. To get a better look, consider dimming the lights in the room. Aside from all the above actions, you have to ensure proper gas pressure in your water. Remove the two connectors of red and white wires from the gas control valve. Use your multimeter, to test how much voltage is going to the igniter. But you might be struggling to figure out what kind of paint to use on garage walls. Wiring issues> Ensure all the snug electrical connections to the gas control valve.Tripped thermal switch> Clean out the vents.> Reset the tripped switch. Step #2: Disconnect thewiring connector of the thermopile from the gas control. So, you should replace it after every 7 years. Lets start: The Honeywell heater users often complain about a major problem: the Honeywell water heater keeps turning off or wont stay lit. If the Honeywell water heater light is not blinking, it may be due to a faulty light switch. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. Step #2: After that time, set the control knob to the pilot position. If your water heater is beeping due to overheating, turn the thermostat down to reduce the temperature. Clean the clogged valve. The other causes of it are: Your water heater can make different types of noises such as rumbling, banging, crackling, ticking, hissing, screeching, and popping. If your pilot light still wont stay lit, the issue is almost always caused by a defective thermocouple. Then, unscrew the manifold tube, pilot tube, and gas supply tube from the gas control valve. Get a new igniter, which looks like the below screenshot. Turn the thermostat to its lowest possible setting. Your water heater wont work properly if the igniter wont spark. Replacement is an easy DIY repair. You can easily replace this part yourself for cheap, or consider hiring a professional to ensure that it is properly installed. A defective thermostat can be changed by professionals to overcome this problem. A carbon deposit may create a restriction making it too difficult for the gas to reach its ignition point. COPYRIGHT 2023. 1 Additionally, these devices are fueled with flammable natural gas. > Ensure all the snug electrical connections to the gas control valve. Start troubleshooting simply by increasing the thermostats temperature as the temperature may turn down anyhow. Dont over-tighten it, and make sure the valve is completely closed. If still, there is no spark, inspect the spark electrode visually. Faulty gas control valve electrical connection. You should not take on any project like this unless you know exactly what you are doing. We will be happy to help you. To better understand how yours works, you will need to know what type you have. Then, set the gas control knob to the Off position to turn off the unit. Move the brush back and forth and clean the base area properly. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. There are several factors for continuously tripping the thermal switch. And then, pry off the igniter from the plastic assembly. If yes, release the valve and set the knob to your desired temperature setting. If the igniter is getting voltage, but it doesn't glow, this indicates that the igniter is defective and should be replaced. Dirt or corrosion on the spark electrode usually interferes with the flow of electricity to the pilot light and can cause it not to ignite. The electronic igniter, will either light the pilot light or will light the gas directly. A thermocouple is an important part of your electric kitchen or gas grill. If youre having trouble getting your water heater to light its pilot light, first check the following spark electrode for dirt and corrosion since this could be your problem.